OpenSim workbench
Browser-local biomechanics, shared viewers and callable modules.
Open a model and run an operation
Files and results stay in this page unless you explicitly download them. This workbench makes no study, patient, storage or Auth request. Duration applies to forward simulation; marker and stored-motion operations retain their original input timeline.
- Open Public → OpenSim from the organization directory or Public apps. No account or invitation is required.
- Load the synthetic pendulum or arm example, or choose a self-contained .osim file.
- For inverse kinematics, choose measured .trc markers with explicit units. For motion analysis, choose .mot/.sto with an explicit inDegrees header.
- Run an operation, replay its computed frames and inspect the linked signal. Download native motion/results and the provenance JSON.
Work with a private study trial
Native files and results require active researcher access in the exact study. Dashboard sharing and patient assignment do not grant native input access. The public local-file workbench remains available without an account.
Native history follows original TRC bytes across dashboard layout versions. Each result retains its frozen input parent, actual operation inputs and completed pipeline stages. A model-only simulation does not imply a participant-specific fit or use of measured markers.
- Choose Open in OpenSim on a study gait dashboard to carry the selected walking trial into the workbench.
- Save a native input version using the original TRC, a compatible model and optional motion. The TRC checksum must match the review audit.
- Run an operation or pipeline, then Save result version. Open earlier inputs/results from Versions without overwriting them.
Supported scope
The first adapter supports model inspection, coordinate posing, forward dynamics, marker inverse kinematics and stored-motion analysis. Models must be self-contained; geometry is resolved only from the pinned bundled catalog. Missing surfaces are identified.
The upstream engine includes more tools, but this adapter exposes only its tested operation set. General saved-study pipeline dispatch, patient-capture adapters, native/cloud adapters, complete PortableOpenSim workbench parity and public hosting are separate integration steps.
Runtime notices, dependency licenses and adapter/build source are available from the workbench. Synthetic browser tests establish calculation and integration behavior; they do not establish clinical validity or native numerical equivalence.